Internal On/Off Microwave Sensor for LED Battens

Internal On/Off Microwave Sensor

An ultra-slim 5.8GHz microwave motion sensor with on/off switching with DIP-switch configurable detection sensitivity (25-100%, hold time (5s to 30min) and daylight threshold (2-50lux or disabled). Up to 6m mounting height, 360° coverage ceiling-mounted or 150° wall-mounted. 

Key Features

Compatible with

What we get asked

A built-in sensor is a compact motion-detection module that sits inside an LED batten during manufacture or custom build, rather than mounting on a ceiling as a separate unit. It gives the batten automatic on/off switching based on movement — light comes on when someone enters, switches off after a set hold time — with no visible sensor showing from below the fitting.

Because the sensor’s integrated into the batten itself, there’s no separate ceiling accessory to install, no extra wiring on site, and no visual clutter on the ceiling line.

Two things specifically:

  • Ultra-slim form factor — the sensor is 22mm deep, so it fits inside the restricted cavity of a batten housing without the sensor dictating how deep the fitting has to be.
  • Patented metal-penetrating antenna — microwaves don’t normally pass through metal, so most built-in sensors miss triggers when they sit behind the metal LED plate inside a batten. The MC098S’s antenna is designed specifically to detect reliably even when mounted behind that LED plate.

 

That combination is why we use this sensor in our batten builds: it fits in a slim housing, and it keeps triggering reliably even with the LED tray sitting between it and the space below.

Depends on mounting height — the sensor supports mounting heights up to 6m, with the optimal position at 3m:

  • At 3-4m mounting — 3m to 10m detection radius (large coverage area for a typical ceiling install)
  • At 6m mounting — 2m to 8m detection radius (good for high-ceilinged installs like workshops and warehouses)

 

Detection angle is 360° when ceiling-mounted and 150° when wall-mounted. The sensitivity is adjustable 25-100% via DIP switches; wall installs usually need the sensitivity reduced to avoid picking up movement outside the intended area.

Three settings, same as the other Merrytek built-in sensors but with more options on each:

  • Detection sensitivity — 100% / 75% / 50% / 25%. Reduce in reflective metal environments to avoid false triggers from microwaves bouncing off hard surfaces.
  • Hold time — 5s / 30s / 90s / 5min / 20min / 30min. Six options cover everything from washroom corridors to warehouse aisles where someone might be stationary for extended periods.
  • Daylight threshold — 2 lux / 10 lux / 30 lux / 50 lux / Disabled. Stops the fitting triggering when there’s already enough natural light.

 

Factory default: 100% sensitivity, 5s hold time, daylight sensor disabled. Set the DIP switches before the batten is closed up — once the housing’s sealed, the switches are hard to reach.

  • 200W inductive (LED driver load)
  • 400W resistive

 

In practical terms, 200W inductive covers a single sensor-variant batten plus one or two more in a linked run from the same sensor — enough for most zone-level installs. For longer runs you’d use a second sensor rather than overloading one.

The sensor is designed to switch one load output only — connecting more than one load output in parallel can damage the sensor.

The sensor module itself is IP20 — indoor use only. But the host batten the sensor’s built into provides whatever outer IP rating the final install needs. So the sensor is fine for use in a batten installed in a damp, dusty or industrial area as long as the batten housing itself is rated for the environment.

Yes. For sensor-enabled battens built to a non-standard spec — custom length, non-standard output, or a particular sensor configuration. Tell us the fitting format and the sensor settings you need (detection area, hold time, daylight threshold), and we’ll quote the build.

Yes. The sensor wires into the mains supply, so installation should always be carried out by a qualified electrician in line with current wiring regulations. If we’re building the sensor into a custom batten or gear tray for you, the sensor arrives pre-wired inside the fitting — the electrician only needs to make the final mains and load connections on site.